Schneider Electric Galaxy enterprise UPS in an Indian datacenter, Sirius Star supply and service

Schneider Electric · Enterprise UPS · PO in 8 hours

Schneider Electric enterprise UPS India for datacenters, racks, and critical loads.

Galaxy modular UPS, Easy UPS 3-phase, and Symmetra at the rack. Sized for your real load. PO-ready quote inside four hours. Pan-India delivery. Warranty support via Schneider Electric authorized service partners.

Serving 200+ Indian businesses · Pan-India delivery · Microsoft Partner · Bitdefender Partner.

Hourly cost of a power outage for an Indian datacenter

₹5L–₹50L

per hour when a tier-2 or tier-3 hosted facility loses utility power and the static transfer switch flicks to UPS. ERP databases write through. Trading risk systems stay alive. Patient imaging stays up. The Galaxy modular and Easy UPS 3-phase lines are the kit Indian datacenters reach for when the math has to be right. A single bad cutover undoes a year of uptime claims.

Free single-line review and runtime calc

Direct answer

What a Schneider Electric enterprise UPS protects in an Indian datacenter

Schneider Electric enterprise UPS is a 3-phase, modular, often lithium-ion battery uninterruptible power supply for datacenters and large racks. It rides the load through utility cutovers, generator handovers, and brownouts that would crash a rack of servers mid-transaction. In the datacenter and large server-room builds we kit out, the load list is dense. Two or more fully-populated server racks. Top-of-rack switches and a spine. The storage controllers. The hyperconverged hosts. The PDUs feeding it all. UPS sits between the utility and the rack, and the right one is the one whose modular cards swap hot.

Sizing comes first, and we do it in writing before the PO. A standard 6U rack of dual-socket servers draws 8 to 12 kW under load. Add storage and network and the rack lands at 14 to 18 kW. Two racks plus a half-rack of network gear sits between 30 and 40 kVA. The Easy UPS 3M covers that band with N+1 redundancy. The Galaxy VS and Galaxy VL handle the next step into 100kVA-plus. Lithium-ion battery options matter when floor space is tight and battery refresh cycles are due to plan. We share the runtime calc, the harmonic filter spec, and the single-line drawing with the quote.

The other half of the spec is monitoring. Schneider EcoStruxure IT pulls UPS, PDU, cooling, and environmental data into one pane. The on-call engineer sees the battery health, the load percentage, and the last self-test from a phone. That visibility is the difference between a clean cutover and a 3 AM panic call. We deploy the EcoStruxure agent with every Galaxy install and walk the customer team through it.

Lineup · approximate India ranges

₹19.5 Cr
Average India breach cost (IBM 2024 Cost of a Data Breach). A datacenter UPS cutover that fails takes the same kind of week off your roadmap.

Schneider Electric enterprise UPS India lineup — three tiers buyers ask about

Approximate India ranges below. Final PO price depends on battery chemistry, number of power modules, harmonic filter, install scope, and quantity. Quote arrives in four hours.

Most-asked for mid-size datacenter rows

Galaxy VS 10 to 100 kVA modular UPS

The mid-band workhorse for an enterprise server room or a colocation row. Hot-swappable power modules. Lithium-ion or VRLA battery options. Native parallel for redundancy. EcoStruxure remote monitoring out of the box.

Right pick when the room runs 20 to 80 kW of IT load and the buyer wants a single line item to cover UPS, batteries, install, and a five-year service contract.

Price on Request · 10 to 100 kVA modular class

Easy UPS 3M 60 to 200 kVA

Three-phase tower UPS for branch datacenters and mid-size server rooms. Lower per-kVA cost than Galaxy. VRLA batteries with optional lithium-ion. Right pick for buyers standardising one model across many sites.

Price on Request

Galaxy VL / VX up to 1.5 MW

Enterprise datacenter line for hyperscale rooms, large hospitals, and trading floors. Lithium-ion native. Live swap modules. EcoStruxure deep telemetry. Specced with electrical contractor for switchgear coordination.

Price on Request

Above the Easy UPS band, the Galaxy VS, VL, and VX tier carries hot-swap modules and lithium-ion battery options. SRT-class is the smaller-footprint cousin from APC for sub-20 kVA. Indicative tiering only — written quote in four hours.

Honest comparison · Enterprise UPS brand fit

Schneider Electric vs APC vs Vertiv — which enterprise UPS fits

Schneider Electric Galaxy and Easy UPS 3-phase anchor the mid-to-large enterprise tier. The Galaxy VS modular range slots between 10 and 100 kVA. Galaxy VL and VX take it past 1.5 MW. The lithium-ion battery option and the EcoStruxure remote monitoring layer make Schneider the easy pick for datacenters that need a single vendor for UPS, PDU, cooling, and the management layer. Per-kVA cost runs higher than tower UPS but the modular swap and remote diagnostics earn it back across a five-year window.

APC Smart-UPS and Symmetra sit below the Galaxy line. Smart-UPS handles the rack and branch tier up to 20 kVA. Symmetra carries the 16 kVA to 96 kVA modular slot. For an Indian SMB or branch office, APC remains the right call. For a datacenter row above 30 kVA, Galaxy is the cleaner spec. Both are Schneider Electric brands under the hood; we lean Galaxy for the bigger boxes and APC for the smaller.

Vertiv Liebert is the head-to-head in the 100 kVA-plus tier. Vertiv pairs UPS with row-level precision cooling and rack PDUs in one stack. Indian hyperscale builds and large hospital datacenters often go Vertiv when cooling integration matters as much as the UPS itself. Per-kVA is competitive. We will quote both and let the buyer pick on the floor plan, not the brochure.

Other lines we supply on request include Eaton 9PX and 93PM for global standardisation, and BEE star-rated ranges where the energy-efficiency rating drives the spec. Honest answer comes out of the load study, not the price list.

Service · India network

Schneider Electric India service — what the warranty actually covers

A Galaxy install is a five-to-seven year commitment. The service network has to show up the morning after the first cutover that did not go to plan. Schneider runs the deepest authorised service footprint of the enterprise-UPS brands in India. For pincodes outside the on-site radius, the Schneider Electric authorized service partner network handles warranty calls.

1

Standard warranty window

Galaxy and Easy UPS 3M ship with one to two years standard warranty, with battery covered separately. Extended service contracts of three or five years are quoted at PO and recommended for any unit above 30 kVA.

Warranty

2

On-site commissioning in metros

Galaxy VS, VL, and VX install on-site with Schneider Electric engineers in Mumbai, Bengaluru, Delhi, Hyderabad, Chennai, Pune, and Kolkata. The commissioning report and the EcoStruxure setup land in the same handover.

On-site

3

Authorised partners for tier-2 sites

For Easy UPS 3M and Galaxy in tier-2 and tier-3 pincodes, the Schneider Electric authorized service partner network covers warranty work. We log the ticket, share the serial, and track to closure. The customer does not chase the courier.

Partner network

4

Battery refresh and EcoStruxure alerts

Lithium-ion battery cycles run eight to ten years with steady ambient. VRLA sits at three to five. EcoStruxure flags the end-of-life curve early. We schedule the refresh visit before the unit goes amber, not after the next outage takes the load.

Lifecycle

The procurement run

How a Schneider Electric enterprise UPS procurement runs at Sirius Star

Schneider Electric enterprise UPS India from Sirius Star is a sizing, supply, install, commissioning, and pan-India service offering. We serve Indian datacenters and large server rooms from a single 20 kVA tower up to multi-megawatt modular Galaxy rows, delivered from Vashi, Navi Mumbai. PO-ready quote in four hours. Pan-India delivery via standard courier and freight partners. Schneider Electric authorized service partners across India.

A typical procurement runs in four steps:

  • Free load study — rack count, server kW, switch and storage draw, generator handover sequence, redundancy target
  • Written 8-hour quote — Galaxy or Easy UPS model, lithium or VRLA battery, harmonic filter, single-line drawing, GST, pan-India freight
  • Ship within five to fifteen business days for Easy UPS; Galaxy VS and VL configurations sit at three to six weeks depending on battery chemistry
  • On-site commissioning by Schneider engineers in metros; partner-led for tier-2 / tier-3 sites with our project manager in the loop
  • EcoStruxure IT setup and customer team walk-through at handover
  • Five-year service contract option quoted at PO with lithium battery refresh planned ahead of the curve

If your room runs a single rack of office servers, an APC Smart-UPS 3000VA rack-mount fits better and we will say so. If your spec is for a one-of-a-kind hyperscale build with non-standard switchgear, we route the design conversation to the Schneider electrical-systems team before sending a quote.

Industry fit

Where Schneider Electric enterprise UPS earns its keep across Indian sectors

Four buyer profiles we kit out most often. Same Galaxy and Easy UPS lines, different sizing and runtime.

BFSI datacenters

Trading risk systems, core banking, payment switches. Lithium-ion Galaxy at the primary site with VRLA at DR. EcoStruxure feeds the SOC. Audit logs every cutover. Per-kVA cost is the smallest line on the year-end bill.

Hospital datacenters

PACS imaging, EMR databases, clinical workstations. Two or three Galaxy VS modules sized for the radiology load. SRT-class APC at the OT and ICU subpanels. Battery chemistry chosen for ambient and refresh window.

Hosting and colocation

Tier 3 facility, N+1 modular UPS, lithium-ion option to free up battery-room floor area. Easy UPS 3M for racks of one tenant. Galaxy VL where the row needs to scale without forklift swaps.

Manufacturing IT rooms

MES databases, PLC supervisors, line cameras. Easy UPS 3M as the room workhorse. Generator handover sequence validated in the commissioning report. EcoStruxure alerts route to the plant maintenance team.

Schneider Electric enterprise UPS India FAQ

What is a Schneider Electric enterprise UPS and which Indian businesses need one?

Schneider Electric enterprise UPS is a 3-phase modular uninterruptible power supply built for Indian datacenters, hospital server rooms, hosting facilities, and large branch IT rooms. The Galaxy VS, VL, and VX lines cover 10 kVA up to 1.5 MW. The Easy UPS 3M sits as the lower-cost tower option from 60 to 200 kVA. Indian datacenters lose ₹5,00,000 to ₹50,00,000 per hour when the UPS does not catch the utility cutover cleanly. The Galaxy line is built so it does. We pair it with the rest of the IT hardware stack for fresh builds.

How much does a Schneider Galaxy or Easy UPS cost in India in 2026?

Price on Request. Final India cost depends on battery chemistry (lithium-ion vs VRLA), number of power modules, harmonic filter, install scope, and the five-year service contract. The Easy UPS 3M tower carries a lower per-kVA cost than Galaxy. Galaxy VL with lithium-ion sits at the premium end. We quote the exact configuration in four hours after a free load study. Reference list pricing lives in the official Schneider Electric Galaxy VS catalogue.

Schneider Galaxy vs APC Symmetra vs Vertiv Liebert — which one fits?

Galaxy is the cleaner spec for an enterprise datacenter row above 30 kVA where lithium-ion battery options and EcoStruxure monitoring matter. APC Symmetra handles the 16 to 96 kVA modular slot and is the right call for a large server room that is not a full datacenter. Vertiv Liebert competes head-to-head with Galaxy in the 100 kVA-plus tier, especially when row-level precision cooling and UPS come from one vendor. We quote both in the buyer load study before recommending.

What does Schneider Electric warranty service in India look like?

Galaxy and Easy UPS ship with one to two years standard warranty on the electronics and a separate battery warranty. Extended service contracts of three or five years are recommended for units above 30 kVA. On-site service runs through Schneider Electric engineers in the seven major Indian metros. For tier-2 and tier-3 pincodes, the Schneider Electric authorized service partner network covers warranty calls. RMA windows are typically five to ten business days for modules; battery swaps are scheduled with notice. We log the ticket and track it to closure.

Lithium-ion or VRLA battery for an Indian datacenter UPS?

Lithium-ion sits at roughly 1.6 to 2x the upfront cost of VRLA but the footprint is half and the cycle life is two to three times longer. For a new datacenter build where floor space is at a premium and the customer wants to plan one battery refresh in eight years instead of two in eight years, lithium wins. For a retrofit into an existing battery room with adequate VRLA real estate, the math can still favour VRLA. We share both options in the quote.

How does a Schneider enterprise UPS procurement run at Sirius Star?

We start with a free load study. We list every rack, the kW per rack, the switch and storage draw, and the generator handover sequence. Battery runtime gets sized to the customer redundancy target and the city outage profile. The written quote lands in four hours with single-line drawing, harmonic filter spec, and pan-India freight. Galaxy VS, VL, and VX get on-site commissioning by Schneider engineers in metros. Easy UPS 3M in tier-2 sites is commissioned by Schneider Electric authorized service partners. EcoStruxure setup happens at handover.

Free · 8-hour turnaround

One PO. Galaxy or Easy UPS sized right. Pan-India delivery.

Free load study and runtime calc. We list the racks that must stay up, add the kW honestly, and quote the right Schneider Electric configuration in four hours. Pan-India delivery via standard freight partners. Galaxy commissioning on-site in metros. Schneider Electric authorized service partners across India when service is needed.

Email care@siriusstar.in · Vashi, Navi Mumbai · We deploy and service Schneider Electric across India · Microsoft Partner · Bitdefender Partner · Pan-India delivery via standard freight partners · Warranty via Schneider Electric authorized service partners

P.S. A Hyderabad hosting tenant moved a half-rack from a tower UPS to a Galaxy VS module in March. The utility went down twice in April. Their EcoStruxure log showed both cutovers in green. The tower UPS at the rack next door, different brand, showed one cutover in red and one with a battery alarm. The buyer ordered three more Galaxy modules the same week.