Vertiv Liebert UPS India for datacenter rows and critical IT rooms.
Liebert APM, ITA2, EXM, and PSI tower lines for Indian server rooms and datacenter rows. Sized for your real load. PO-ready quote inside four hours. Pan-India delivery. Warranty via Vertiv authorized service partners.
Serving 200+ Indian businesses · Pan-India delivery · Microsoft Partner · Bitdefender Partner.
Hourly cost of a power outage for an Indian datacenter
₹5L–₹50L
per hour when a hosted facility or critical IT room loses utility power and the UPS misses the cutover. ERP transactions roll back. Trading risk engines reset. CCTV NVRs blank. Vertiv built the Liebert APM and ITA2 lines precisely to keep that hour from ever happening. The math against a single bad outage rarely needs more than five minutes.
Free single-line review and battery runtime calc
What a Vertiv Liebert UPS protects in an Indian server room
Vertiv Liebert UPS is an online double-conversion or modular uninterruptible power supply built for Indian datacenters, large server rooms, and critical IT cabinets. It rides the load through utility cutovers, generator handovers, and the brownouts the Indian grid serves up daily. In the rooms we kit out, the load list reads like a small datacenter inside a corporate office. Two or three fully-populated server racks. Storage controllers. The core switch and spine. A PDU stack per rack. CCTV NVR if the security desk lives in the same room.
Sizing is the first conversation. A standard rack of dual-socket servers carries 8 to 12 kW under load. Add storage and the spine and a tightly-loaded row hits 30 to 50 kVA. The Liebert ITA2 6 to 20 kVA tower line covers the smaller server-room side. The APM modular line takes it from 30 kVA into the 600 kVA tier with hot-swap power modules. EXM and EXL go above that for true datacenter rows. We share the runtime calc, the harmonic profile, and the single-line drawing with the quote.
Monitoring is the second half. Vertiv LIFE Services pulls UPS telemetry into a remote diagnostics pane and surfaces battery health, load percentage, and cutover history. For sites with Vertiv rack PDUs and Liebert cooling, the same pane carries the rest of the row. That visibility is what turns a 3 AM panic call into a planned battery refresh visit two weeks earlier.
Vertiv Liebert UPS India lineup — three tiers buyers ask about
Approximate India ranges below. Final PO price depends on battery chemistry, harmonic filter, install scope, and quantity. Quote arrives in four hours.
Liebert APM 30 to 600 kVA modular UPS
The mid-band workhorse for an Indian server room or a datacenter row. Hot-swappable power modules. Lithium-ion or VRLA batteries. Native parallel for redundancy. Vertiv LIFE Services for remote diagnostics.
Right pick when the room runs 25 to 400 kW of IT load and the buyer wants the option to grow the UPS in 30 kVA modules instead of swapping out the chassis.
Price on Request · 30 to 600 kVA modular class
Liebert ITA2 6 to 20 kVA tower
Online double-conversion tower for a single-rack server room or a critical IT cabinet. Right pick when the load sits between 4 and 16 kW and the room does not justify a modular chassis. Compact footprint, internal batteries, external battery cabinet option.
Price on Request
Liebert EXM / EXL up to 1.2 MW
Enterprise datacenter line for hyperscale rooms, large hospitals, and government datacenters. Lithium-ion native on EXL. Live swap modules. LIFE Services deep telemetry. Coordinated with electrical contractor at the switchgear stage.
Price on Request
Below ITA2, the PSI tower line covers 1 to 3 kVA for single-server or small comms-cabinet loads. SRT-class is the APC option in the same band. Indicative tiering only — written quote in four hours.
Vertiv vs APC vs Eaton — which datacenter UPS fits
Vertiv Liebert APM and EXM anchor the datacenter-row tier in India. APM modular slots between 30 and 600 kVA. EXM and EXL take it past 1 MW. The advantage we see most often: when the same buyer needs UPS, rack PDU, and row-level precision cooling in one contract, Vertiv ships all three with one LIFE Services subscription. That single-vendor stack saves a quarter of the commissioning time on a green-field build.
APC Smart-UPS and Symmetra are the head-to-head below 100 kVA. APC Smart-UPS owns the rack and branch tier. Symmetra carries the 16 to 96 kVA modular slot. For an Indian SMB or a single-rack room, APC remains the cleaner spec. For a row of three racks or more, Vertiv APM is the easier scale-out.
Eaton 9PX and 93PM compete head-to-head in the 30 to 200 kVA band. Eaton runs the deepest cost discipline of the three on per-kVA pricing. Right pick for buyers standardising on Eaton globally or running an Eaton xStorage battery stack. The trade-off is the slimmer service partner network outside the seven major Indian metros. We will quote both honestly.
Other lines on the table when the math demands include Schneider Galaxy VS and VL when the buyer is already on EcoStruxure, and the BEE star-rated ranges where the energy-efficiency rating drives the spec. The honest answer lands in the load study.
Vertiv India service — what the warranty actually covers
A Liebert APM install is a five-to-seven year commitment. The Vertiv Customer Engagement Centre runs 24×7 from Pune. On-site engineers cover the seven major Indian metros directly. For tier-2 and tier-3 pincodes, the Vertiv authorized service partner network handles warranty work and we keep the project manager in the loop.
Standard warranty window
Liebert ITA2, APM, and EXM ship with one to two years standard warranty on the electronics, with battery covered separately. Extended service contracts of three or five years are quoted at PO and recommended for any unit above 30 kVA.
Warranty
On-site commissioning in metros
APM, EXM, and EXL get on-site install by Vertiv engineers in Mumbai, Bengaluru, Delhi, Hyderabad, Chennai, Pune, and Kolkata. The commissioning report and LIFE Services activation land at the handover.
On-site
Vertiv authorized partners for tier-2
For ITA2 and APM in tier-2 and tier-3 pincodes, the Vertiv authorized service partner network covers warranty work. We log the ticket, share the serial, and track to closure. The customer does not chase the courier.
Partner network
Battery refresh and LIFE Services alerts
Lithium-ion battery cycles run eight to ten years. VRLA sits at three to five depending on ambient. LIFE Services flags the end-of-life curve early. We schedule the refresh visit before the unit goes amber, not after the next outage.
Lifecycle
How a Vertiv Liebert UPS procurement runs at Sirius Star
Vertiv Liebert UPS India from Sirius Star is a sizing, supply, install, commissioning, and pan-India service offering. We serve Indian server rooms and datacenter rows from a single ITA2 6 kVA tower up to a row of APM modular chassis, delivered from Vashi, Navi Mumbai. PO-ready quote in four hours. Pan-India delivery via standard freight partners. Vertiv authorized service partners across India.
A typical procurement runs in four steps:
- Free load study — rack count, server kW, switch and storage draw, generator handover sequence, redundancy target
- Written 8-hour quote — Liebert model, lithium or VRLA battery, harmonic filter, single-line drawing, GST, pan-India freight
- Ship within five to fifteen business days for ITA2 and PSI; APM and EXM configurations sit at three to six weeks depending on battery chemistry
- On-site commissioning by Vertiv engineers in metros; partner-led for tier-2 / tier-3 sites with our project manager in the loop
- LIFE Services setup and customer team walk-through at handover
- Five-year service contract option quoted at PO with lithium battery refresh planned ahead of the curve
If your room runs a single workstation and a NAS, an APC Smart-UPS 1500VA tower fits better and we will say so. If your spec is a 2 MW hyperscale build with non-standard switchgear, we route the design conversation to the Vertiv solutions team before sending a quote.
Where Vertiv Liebert earns its keep across Indian sectors
Four buyer profiles we kit out most often. Same APM and ITA2 lines, different sizing and runtime.
BFSI server rooms
Core banking, payment switch, trading risk. APM modular at primary with VRLA at DR. LIFE Services feeds the operations team. Audit logs every cutover. The cost of a missed cutover is the smallest line on the year-end risk register.
Hospital IT rooms
PACS imaging, EMR databases, lab analysers. ITA2 20 kVA at the OT-adjacent rack. APM module at the main server room. Battery chemistry chosen for ambient and refresh window.
Hosting and colocation
Tier 3 facility, N+1 modular UPS, lithium-ion option to free up battery-room floor area. APM for racks of one tenant. EXM where the row needs to scale without forklift swaps.
Manufacturing IT rooms
MES databases, PLC supervisors, line cameras. ITA2 as the rack workhorse. Generator handover sequence validated in the commissioning report. LIFE Services alerts route to the plant maintenance team.
Vertiv Liebert UPS India FAQ
What is Vertiv Liebert UPS and which Indian businesses need it?
Vertiv Liebert UPS is an online double-conversion or modular uninterruptible power supply built for Indian datacenter rows and critical IT rooms. The APM line covers 30 to 600 kVA with hot-swap modules. ITA2 sits at 6 to 20 kVA for single-rack rooms. EXM and EXL go past 1 MW for hyperscale builds. Indian datacenters lose ₹5,00,000 to ₹50,00,000 per hour when the UPS does not catch the utility cutover. The Liebert line is built so it does. We pair it with the rest of the IT hardware stack for fresh server rooms.
How much does a Liebert APM or ITA2 cost in India in 2026?
Price on Request. Final India cost depends on battery chemistry, harmonic filter, install scope, and the five-year service contract. The ITA2 tower carries a lower per-kVA cost than APM modular. APM with lithium-ion sits at the premium end of the mid-band. We quote the exact configuration in four hours after a free load study. Reference list pricing lives in the official Vertiv Liebert catalogue.
Vertiv vs APC vs Eaton — which datacenter UPS fits?
Vertiv APM is the cleaner spec for a datacenter row of three racks or more, especially when the buyer also needs row-level cooling and rack PDUs from the same vendor. APC Symmetra owns the 16 to 96 kVA modular slot for large server rooms that are not full datacenters. Eaton 9PX and 93PM compete head-to-head in the 30 to 200 kVA band, with stronger per-kVA cost discipline. We quote at least two of the three on every datacenter brief and let the buyer pick on the floor plan.
What does Vertiv warranty service in India look like?
Liebert ITA2, APM, and EXM ship with one to two years standard warranty on the electronics and a separate battery warranty. The Vertiv Customer Engagement Centre runs 24×7 from Pune. On-site engineers cover the seven major Indian metros directly. For tier-2 and tier-3 pincodes, the Vertiv authorized service partner network handles warranty calls. RMA windows are typically five to ten business days for modules. We log the ticket and track it to closure.
Lithium-ion or VRLA battery for a Liebert APM?
Lithium-ion sits at 1.6 to 2x the upfront cost of VRLA but the footprint is half and the cycle life is two to three times longer. For a new server room with limited battery-room floor area and a plan to refresh once in eight years instead of twice, lithium wins on TCO. For a retrofit into an existing VRLA battery room with adequate real estate, VRLA can still pencil out cheaper. We share both options in the quote.
How does a Vertiv enterprise UPS procurement run at Sirius Star?
We start with a free load study. We list every rack, the kW per rack, the switch and storage draw, and the generator handover sequence. Battery runtime gets sized to the customer redundancy target. The written quote lands in four hours with single-line drawing, harmonic filter spec, and pan-India freight. APM, EXM, and EXL get on-site commissioning by Vertiv engineers in metros. ITA2 in tier-2 sites is commissioned by Vertiv authorized service partners. LIFE Services activation happens at handover.
One PO. Liebert APM or ITA2 sized right. Pan-India delivery.
Free load study and runtime calc. We list the racks that must stay up, add the kW honestly, and quote the right Vertiv Liebert configuration in four hours. Pan-India delivery via standard freight partners. APM commissioning on-site in metros. Vertiv authorized service partners across India when service is needed.
Email care@siriusstar.in · Vashi, Navi Mumbai · We deploy and service Vertiv Liebert across India · Microsoft Partner · Bitdefender Partner · Pan-India delivery via standard freight partners · Warranty via Vertiv authorized service partners
P.S. A Pune hosting operator added two APM 90 kW modules to an existing chassis last quarter without a forklift, without a downtime window, and without a single line in the LIFE Services log going amber. The customer rang us to ask what we had done. The honest answer was nothing fancy. The chassis was built for it.